Traps best serve this application when they:
These requirements combine to make the float and thermostatic (F&T) trap the best selection for this application. A suitable alternative would be an inverted bucket (IB) trap with an external thermostatic air vent.
| Characteristic | Inverted Bucket | F&T | Disc | Thermostatic | Differential Controller | |
| A | Method of Operation | Intermittent | Continuous | Intermittent | Intermittent | Continuous |
| B | Energy Conservation (Time in Service) | Excellent | Good | Poor | Fair | Excellent |
| C | Resists Wear | Excellent | Good | Poor | Fair | Excellent |
| D | Resists Corrosion | Excellent | Good | Excellent | Good | Excellent |
| E | Resists Hydraulic Shock | Excellent | Poor | Excellent | Poor | Excellent |
| F | Vents Air and CO2 at Steam Temperature | Yes | No | No | No | Yes |
| G | Vents Air at Very Low Pressure (1/4 psig)(.02 bar) | Poor | Excellent | NR | Good | Excellent |
| H | Handles Start-up Air Loads | Fair | Excellent | Poor | Excellent | Excellent |
| I | Operates Against Back Pressure | Excellent | Excellent | Poor | Excellent | Excellent |
| J | Resists Damage from Freezing | Good | Poor | Good | Good | Good |
| K | Can Purge System | Excellent | Fair | Excellent | Good | Excellent |
| L | Performs on Very Light Loads | Excellent | Excellent | Poor | Excellent | Excellent |
| M | Responds to Slugs of Condensate | Immediate | Immediate | Delayed | Delayed | Immediate |
| N | Handles Dirt | Excellent | Poor | Poor | Fair | Excellent |
| O | Comparative Physical Size | Large | Large | Small | Small | Large |
| P | Handles "Flash Steam" | Fair | Poor | Poor | Poor | Excellent |
| Q | Mechanical Failure (Open -- Closed) | Open | Closed | Open | Open, Closed | Open |
| First Choice | Alternative | Overriding condition |